EVOLU Classic thermometer mercury-free

Product no.: 9500188
8.20


Mercury Free Thermometer EVOLU Classic
Instruction For Use
a. Mercury free clinical thermometer is a kind of measuring device for patient’s temperature, and it can be used to measure the temperature of patient’s mouth or armpit or anus.
b. The product is in compliance with EN12470-1:2000+A1:2009, Clinical thermometers - Part 1: Metallic liquid-in glass thermometers with maximum device:
1. the conditions of use: measuring temperature range should be between 35℃ to 42℃, and the environment temperature should be 20℃ to 30℃; if the temperature for storage is less than 20℃, please keep the thermometer at room temperature for at least 1-2 hours before use or test.
2. The temperature of storage and transport : from -10℃ to +42℃
c. Operation procedures
1.The liquid column shall be below the lowest numbered scale mark before use, then clean and disinfect the clinical thermometer with disinfectant solution.
Notice for shaking down: catch the tail part of the thermometer by thumb and forefinger tightly and carefully, swing the thermometer lightly several times until the liquid is down.
2.      Be careful to put it below the tongue of patients for oral clinical thermometer and tell them to close their mouth tightly.
3. A clinical thermometer for rectal use is applied some water-based lubricant before inserting it in the anus.
4. Be careful to put it below the armpit of patients for armpit clinical thermometer and tell them to tight it tightly.
5. Please read the number of the clinical thermometer about 5 minutes after above measuring steps.
6. After use, shake down the metallic liquid down, then clean it and put in the plastic case to avoid any damages.
d. Warning
1. It is not suitable to use oral clinical thermometers for not more than ten years’ old children;
2. Warn patients against chewing, speaking and playing when the clinical thermometers are below the tongue of patients;
3. Need to let patient lie quietly and hold another end of the clinical thermometers for rectal use in case it is inserted too deep, or it slips from the anus.
4. Avoid having a bath, eating or smoking half an hour before taking body temperature;
5. It is not designed for special applications (e.g. thermometers for premature babies, ovulation);
6. The metallic liquid is an alloy consisting of gallium, indium and tin, this clinical thermometer should be handled with care. In particular, care should be taken to avoid dropping the instrument or treating it in any way that could result in damage. When the clinical thermometers are broken, cleaning split metallic liquid by a damp cloth with soap suds.
7. It is recommended to inspect the clinical thermometer once a year for accuracy.
e. Disposal of the Clinical thermometers
Disposal of all waste material should be in accordance with local guidelines
 
 
Produced for FORANS International AG, Switzerland
Wuxi Medical Instrument Factory Co., Ltd.